Filter Results By:

Products

Applications

Manufacturers

Showing results: 211 - 225 of 226 items found.

  • Digital H.V. Insulation Tester(10kV)

    6310 IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 20 TΩ● 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on

  • Digital H.V. Insulation Tester(5kV)

    6305A IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on

  • Digital H.V. Insulation Tester(5kV)

    6304 IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 1.9mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display

  • CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel

    40-200-008 - Pickering Interfaces Ltd.

    This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • PXI Single 10 Channel MUX, XLR Connectors

    40-735-902-S2 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI Single 36 Channel MUX, SMB Connectors

    40-735-912-S4 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI Single 18 Channel MUX, BNC Connectors

    40-735-902-S3 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI Dual 18 Channel MUX, 96-Pin SCSI Connector

    40-735-912-S1 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI 36 Channel Data Comms MUX, 96-pin SCSI

    40-735-912 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI 18 Channel Data Comms MUX, 96-pin SCSI

    40-735-902 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • 32-CH 12-Bit 100 kS/s Isolated Analog Input Card

    PCI-9113A - ADLINK Technology Inc.

    ADLINK PCI-9113A is a 32-CH, 12-bit, 100 kS/s isolated analog input card. The PCI-9113A provides analog inputs with 3 programmable input ranges for both bipolar and unipolar inputs. The 32-CH single-ended analog inputs can be converted to 16-CH differential analog inputs, which improve the noise rejection in harsh industrial environments. The analog inputs are isolated from the PC's system ground. This feature not only protects the PC from being damaged from surges on the signal lines, but also eliminates ground loops and common-mode problems commonly seen in industrial measurement applications. The PCI-9113A provides custom circuit area for input signal conditioning. Either signal attenuation or filtering can be applied on per channel basis. With all the features, ADLINK PCI-9113A delivers cost-effective and reliable data acquisition capabilities for ATE, sensor monitoring, data logging, power transmission, and a broad variety of industrial measurement applications.

  • Deep Ultraviolet Spectrophotometer System

    VUVAS-10X - McPherson, Inc.

    A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions.

  • Instrument Systems General Accessories

    Konica Minolta Sensing Americas, Inc

    Instrument Systems General Accessories current range of optical probes and measurement adapters using fiber optics as a means to transport light in the spectrometer was a primary goal sought by Instrument Systems from the beginning of their product development. With the increased research and the recent advances made in fiber optics it is a goal that has come to fruition. Having striven to incorporate fiber optic technology into their spectrometer systems. Instrument Systems has been working on creating top of the line fiber optic accessories. This not only diversifies the already wide application possibilities for Instrument Systems Spectrometers, but makes them more universally and effortlessly installed. Whether it’s measuring spectral transmission properties in normal light incidence, measuring ultra violet or infrared, or collecting radiation and measurements of irradiance, Instrument Systems has developed an accessory to meet your specific needs. For simplicity and ease of use Instrument Systems has made all of their accessories “plug-and-play”. This means installing and expanding the capabilities of your Instrument Systems Spectrometer has never been easier.

  • EMI Receiver

    KH3935 - Beijing KeHuan Century EMC Technology Co,.LTD

    KH3935 type EMI test receiver interference test receiver is fully automatic, is EMI major tool for testing. The frequency range of the KH3935 receiver is from 9kHz to 30MHz , which satisfies the power line disturbance power test. After configuring the artificial power network, the power terminal disturbance voltage test can be performed. The machine has fast test speed, strong maneuverability, stable performance, Advantages such as convenient test data processing. The KH3935 receiver uses a USB interface for data transmission, and supports USBinterface peripheral devices such as printers, mice, keyboards, etc. The machine is equipped with a high-speed and large-capacity hard disk, which stores a variety of external device data, and supports plug and play. External test equipment. The software is self-developed by our company, using windows as the carrier, users who are familiar with the operation of windows can quickly get started. The machine can independently carry out test work without additional control equipment for control operations, which fundamentally solves the problem of interference sources. The measurement results can be input to the hard disk in the receiver or stored in a floppy disk through a floppy drive or printed out directly or savedusing a USB storage device. The detailed measurement report can be printed directly according to user needs without additional editing.

  • EMI Receiver

    KH3939 - Beijing KeHuan Century EMC Technology Co,.LTD

    KH3939 type EMI test receiver interference test receiver is fully automatic, is EMI major tool for testing. The frequency range of the KH3939 receiver is from 9kHz to 300MHz , which satisfies the power line disturbance power test. After configuring the artificial power network, the power terminal disturbance voltage test can be carried out. The machine has fast test speed, strong maneuverability, stable performance, Advantages such as convenient test data processing. The KH3939 receiver uses a USB interface for data transmission, and supports USBinterface peripheral devices such as printers, mice, keyboards, etc. The machine is equipped with a high-speed and large-capacity hard disk, which stores a variety of external device data, and supports plug and play. External test equipment. The software is self-developed by our company, using windows as the carrier, users who are familiar with the operation of windows can quickly get started. The machine can independently carry out test work without additional control equipment for control operations, which fundamentally solves the problem of interference sources. The measurement results can be input to the hard disk in the receiver or stored in a floppy disk through a floppy drive or printed out directly or savedusing a USB storage device. The detailed measurement report can be printed directly according to user needs without additional editing.

Get Help